UC Series Set Screw Insert Ball Bearings

UC / RB 200 Series insert bearing for applications where a direct shaft lock is preferred and the housing is selected separately. Catalog evidence covers the dual set screws on extended inner ring and fits matching spherical-seat housings; confirm the exact size row and operating conditions before ordering.

MOQ: 50 pcs. Minimum order value USD 1,500; mixed orders and trial quantities welcome.

This is the right catalog family when the replacement decision centers on a direct shaft lock is preferred and the housing is selected separately. In the supplied catalog, UC / RB 200 Series is shown as insert bearing with dual set screws on extended inner ring and fits matching spherical-seat housings. For UC / RB 200 Series, quotation work moves faster when the source designation, shaft or bore dimension and the controlling mounting measurements are checked before optional seal, grease or housing requests are discussed.

UC Series Set Screw Insert Ball Bearings technical drawing
Catalog-derived product drawing / mounting view.
Series
UC / RB 200 Series
Shaft Lock
Dual set screws on extended inner ring
Mounting
Fits matching spherical-seat housings
Evidence
Supplied catalog, PDF page 6

Product Role

The mechanical role is to support the rotating member while preserving a serviceable connection to the frame. With UC / RB 200 Series, matching the bore without checking fits matching spherical-seat housings can produce a part that fits the shaft but not the machine.

Construction & Fit

The cataloged construction combines the bearing function with the surrounding mounting geometry shown on the source page. For UC / RB 200 Series, that chain includes dual set screws on extended inner ring at the shaft and fits matching spherical-seat housings at the machine. Where the UC / RB 200 Series bearing-unit arrangement permits limited static angular accommodation, the shaft line still has to be set correctly before final tightening.

Applications

Common duty examples from this bearing-unit class include conveyors, fan shafts, agricultural machinery, packaging equipment and general transmission supports. A drawing match for UC / RB 200 Series is only part of the decision; contamination, washdown and available service space can change the preferred specification.

Engineering Review

A UC insert is usually selected before the housing when the machine builder already knows the support form but wants a set-screw bearing core. The important replacement check is not only the nominal shaft diameter. Compare inner-ring width, the spherical outside profile, the lock position and the housing seat used by the existing assembly. A UC insert that slides onto the shaft can still be wrong if its width or outside geometry does not match the housing in service.

For maintenance work, photograph the insert while it is still seated and record which side gives access to the two locking screws. If shaft marking is heavy, inspect the fit before installing another bearing. When the old housing is reusable, include its casting designation in the enquiry; that helps keep the insert-to-housing relationship intact instead of treating UC as a universal loose bearing.

A useful workshop check for UC inserts is to compare shaft witness marks with the two set-screw positions. Uneven marking can point to poor seating or a shaft-fit issue. Keep the original insert and housing paired during identification, clean the code area carefully, and record any seal damage before washing the part. Those observations can explain why an apparently correct replacement has a short service life.

If the shaft will be reused, run a fingernail over the set-screw witness marks and measure nearby diameter rather than assuming the untouched area represents the working fit. A local ridge can stop the new UC inner ring from sliding into position and can tempt installers to use impact that should never pass through the rolling elements.

Technical Specifications

Parameter Specification / Selection Note
Product form Insert bearing
Catalog series UC / RB 200 Series
Shaft locking Dual set screws on extended inner ring
Machine mounting Fits matching spherical-seat housings
Material confirmation Confirm the exact material grade for UC / RB 200 Series on the quotation or current drawing; this page does not infer grade from appearance
Seal / lubrication review Check the selected UC / RB 200 Series designation together with speed, contamination and cleaning conditions
Technical source Supplied bearing catalog, PDF page 6
UC Series Set Screw Insert Ball Bearings dimension and specification table
Catalog specification and dimensional reference. Confirm the exact row before ordering.

Dimensional Data

The table below gives catalog-backed core dimensions for UC / RB 200 Series where the scan is legible. For UC / RB 200 Series, the specification image in the gallery remains the reference for the complete drawing and every dimension on the selected size row.

Bearing d (mm) D (mm) B (mm) C (mm) S (mm) Dynamic Cr (kN) Static C0r (kN) Mass (kg)
UC204 20 47 31 16 12.7 9.88 6.65 0.18
UC205 25 52 34.1 17 14.3 10.8 7.88 0.21
UC206 30 62 38.1 19 15.9 15.0 11.2 0.32
UC207 35 72 42.9 20 17.5 19.8 15.2 0.48
UC208 40 80 49.2 21 19 22.8 18.2 0.64
UC209 45 85 49.2 22 19 24.5 20.8 0.68
UC210 50 90 51.6 23 19 27.0 23.2 0.8

Selection Notes

Begin with the dimensions that cannot move in the existing machine. A UC / RB 200 Series replacement needs the actual shaft measurement, the controlling fits matching spherical-seat housings dimensions and confirmation of dual set screws on extended inner ring. Photograph UC / RB 200 Series together with its surrounding structure so the reviewer can see access, adjacent shoulders and possible interference.

Mounting & Integration

Clean the shaft, seat the insert squarely in the housing, rotate the inner ring into its working position, then tighten both set screws to the specified torque for the screw size. The main installation hazard for UC / RB 200 Series is that using the wrong shaft tolerance or tightening the set screws unevenly can reduce concentricity and make later removal difficult. Before startup, inspect UC / RB 200 Series from both sides for trapped seals, contact marks or hardware that could rub once the shaft turns.

Maintenance & Inspection

Check seal condition and running temperature after commissioning; replenish grease only when the housing arrangement provides a relubrication path and the duty actually requires it. For UC / RB 200 Series, keep maintenance notes tied to the installed position so repeated issues can be separated from random one-time events.

Customization & RFQ

For a UC / RB 200 Series replacement enquiry, send the complete code if it is readable, plus shaft size and the mounting dimensions that position the unit. Add a plain-language environment note for UC / RB 200 Series, covering water, abrasive dust, chemicals, cleaning practice and temperature extremes where relevant. Ever Power Netherlands Branch can then review options for UC / RB 200 Series against the supplied application instead of presenting unverified material, seal or grease claims as standard catalog facts.

Cataloged Models

The documented scope on this page includes UC202–UC218 metric and inch-bore variants; RB variants shown alongside selected UC sizes. Keep the complete UC / RB 200 Series suffix or bore variant when matching existing equipment because a shortened code can hide a different locking or dimensional arrangement.

Product FAQ

What should be matched first when replacing UC / RB 200 Series?

Start with the actual shaft or bore measurement and the fits matching spherical-seat housings. For UC / RB 200 Series, then compare the full designation and the dual set screws on extended inner ring. Use the UC / RB 200 Series catalog drawing as the dimensional reference; photographs support identification but do not replace measurements.

Can the locking method be changed to another bearing family?

Only after an engineering interchange check. The dual set screws on extended inner ring used on UC / RB 200 Series can change bearing width, shaft preparation, hardware access and service sequence. A redesign around UC / RB 200 Series may be possible, but it should not be presented as a direct catalog substitution.

How should sealing and lubrication requirements be specified?

Describe the actual UC / RB 200 Series duty: speed, operating hours, contamination, cleaning or washdown and temperature. The UC / RB 200 Series family name does not establish every seal or grease detail, so confirm the final arrangement for the chosen designation.

What should be included with the quotation request?

Send the UC / RB 200 Series code or measured replacement dimensions, quantity, machine type, shaft size, speed, load direction and installation photos. Because this product is insert bearing, also show the dimensions that control the mounting face or frame position.

Evidence Note

Technical evidence for UC / RB 200 Series comes from the supplied scanned catalog, including its series drawing and model table. The gallery drawing for UC / RB 200 Series is a direct catalog crop, not an AI-generated technical illustration. Any application visualization added later for UC / RB 200 Series should be treated as illustrative rather than as dimensional evidence.

Source boundary for UC / RB 200 Series: geometry and transcribed dimensions are based on the supplied catalog, PDF page 6. For UC / RB 200 Series, Drive research was restricted to private buyer context, while public web research supported terminology and WP All Import workflow.

Prepare the Bearing RFQ
For UC / RB 200 Series, send the existing designation, shaft size, mounting dimensions, speed, load direction and useful application photos. Ever Power Netherlands Branch can review the identification data before quotation.

Email sales@netherlandsdrive.com