This catalog group is useful where maintenance or design work requires the housing itself is being replaced while a compatible insert bearing is selected separately. In the supplied catalog, S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB is shown as bare cast housings with not applicable; housing only and pillow, flange, take-up, hanger and bracket housing geometries. For S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB, quotation work moves faster when the source designation, shaft or bore dimension and the controlling mounting measurements are checked before optional seal, grease or housing requests are discussed.

Product Role
A reliable application uses the cataloged bearing arrangement as one mechanical system linking shaft, rolling elements and frame. A S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB match is therefore strongest when the full code and the pillow, flange, take-up, hanger and bracket housing geometries are confirmed together with the shaft measurement.
Construction & Fit
The source image is especially useful here because it shows the actual series geometry beside its dimensional table. For S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB, that chain includes not applicable; housing only at the shaft and pillow, flange, take-up, hanger and bracket housing geometries at the machine. For S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB, small assembly-angle tolerance does not remove the need for a straight shaft, a stable mounting face and aligned neighboring supports.
Applications
This configuration is seen in maintenance rebuilds, bearing-unit repair, custom assembly and replacement programs for multiple mounted-bearing housing forms. The same S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB designation can see very different speeds and load directions, so application data still belongs in the RFQ.
Engineering Review
The cast-housing section is different from a complete mounted-bearing listing because the housing can be supplied or identified separately from the insert. The catalog covers pillow-block, two-bolt flange, square flange, tapped-base, take-up, round cartridge, hanger and other cast forms. Selection must therefore start with the housing geometry and the compatible insert family; an empty casting is not a complete bearing unit by itself.
During overhaul, inspect the spherical seat, mounting holes, grease passage and any anti-rotation features before deciding to reuse a housing. Cracks, fretting or an enlarged bolt hole can make a visually acceptable casting unsuitable for another insert. For an RFQ, send the casting designation, bore-seat condition, mounting dimensions and the insert number currently used. That separates housing replacement from a request for a fully assembled unit.
A bare cast housing deserves a seat-condition inspection before a new insert is ordered. Use light and a clean cloth to reveal fretting, cracking or a polished patch around the spherical bore. Check the grease passage for blockage and verify the mounting holes have not been stretched by movement. If the casting is damaged, pairing it with a new insert may only transfer the same loading problem into the replacement bearing.
When evaluating a loose cast housing, mark the bearing-seat high point and any fretted area before cleaning. The location of damage can indicate how the insert was loaded or whether it moved in service. Keeping this evidence with the casting code helps decide whether the housing can be reused, machined under an approved repair plan, or replaced entirely.
Technical Specifications
| Parameter | Specification / Selection Note |
|---|---|
| Product form | Bare cast housings |
| Catalog series | S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB |
| Shaft locking | Not applicable; housing only |
| Machine mounting | Pillow, flange, take-up, hanger and bracket housing geometries |
| Material confirmation | Confirm the exact material grade for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB on the quotation or current drawing; this page does not infer grade from appearance |
| Seal / lubrication review | Check the selected S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB designation together with speed, contamination and cleaning conditions |
| Technical source | Supplied bearing catalog, PDF pages 43-44 |
Dimensional Data
For S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB, the transcribed values below are limited to dimensions that could be read confidently from the supplied catalog. Confirm the full S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB row against the accompanying specification image before a production order.
| Catalog Series | Shaft Lock / Interface | Unit Form | Mounting Geometry | Source |
|---|---|---|---|---|
| S.UCP200 | Housing only | Pillow block cast housing | Base mount | PDF page 43 |
| S.UCFL200 | Housing only | Two-bolt flange cast housing | Oval flange | PDF page 43 |
| S.UCF200 | Housing only | Square flange cast housing | Four-bolt flange | PDF page 43 |
| S.UCPW200 | Housing only | Tapped-base cast housing | Tapped base | PDF page 43 |
| S.UCT200 | Housing only | Take-up cast housing | Sliding frame | PDF page 44 |
| S.UCFC200 | Housing only | Flange cartridge cast housing | Round flange | PDF page 44 |
| S.UCHA200 | Housing only | Hanger cast housing | Suspended mount | PDF page 44 |
| S.UCFB200 | Housing only | Three-hole/bracket housing | Bracket mount | PDF page 44 |
Selection Notes
The most efficient enquiry starts with the old unit code and a measured sketch of the installation. Measure the S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB shaft interface and the fixed geometry around its pillow, flange, take-up, hanger and bracket housing geometries; then confirm the not applicable; housing only matches the service method. If inch and metric possibilities for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB are close, send the measured value rather than a converted or remembered nominal size.
Mounting & Integration
Inspect the shaft and insert before reusing them, clean the spherical seat, verify the grease path and anti-rotation details where present, and install the housing on an undistorted mounting surface. The main installation hazard for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB is that a bare housing should not be ordered from the external shape alone; spherical seat, bolt pattern, center height and compatible insert series must all match. Before returning S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB to service, rotate the shaft manually if the machine can be made safe and verify that tightening has not introduced binding.
Maintenance & Inspection
Housing cracks, fretted seats and enlarged mounting holes are replacement criteria; painting or cosmetic repair should never hide damage at the bearing seat. For S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB, keep maintenance notes tied to the installed position so repeated issues can be separated from random one-time events.
Customization & RFQ
For a direct S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB replacement, document the old unit, shaft and mounting face before asking for material or sealing alternatives. If S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB works in dirty or wet service, send that information with the mechanical dimensions so optional protection can be evaluated against a real duty. Ever Power Netherlands Branch can then review options for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB against the supplied application instead of presenting unverified material, seal or grease claims as standard catalog facts.
Cataloged Models
Documented variants are S.UCP200 pillow block cast housings; S.UCFL200 two-bolt flange cast housings; S.UCF200 square flange cast housings; S.UCPW200 tapped-base housings; S.UCT200 take-up housings; S.UCFC200 round cartridge housings; S.UCHA200 hanger housings; S.UCFB200 three-hole / bracket housings. A S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB enquiry should preserve the precise code shown on the drawing rather than substituting a family nickname.
Product FAQ
What should be matched first when replacing S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB?
Treat the fixed machine dimensions as the first filter for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB: shaft size plus pillow, flange, take-up, hanger and bracket housing geometries. After that, verify the complete S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB designation and not applicable; housing only against the source drawing before discussing optional features.
Can the locking method be changed to another bearing family?
A different lock can be considered, but it becomes a machine-selection decision rather than a simple S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB replacement. For a S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB redesign, check shaft condition, axial space, bearing width and tool access before approving the change.
How should sealing and lubrication requirements be specified?
State what reaches the S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB location and how often the machine runs. Include water, abrasive material, cleaning agents and temperature. Sales engineering can then check the available S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB seal and lubrication arrangement against the exact size.
What should be included with the quotation request?
Provide the S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB designation, shaft measurement, mounting sketch, operating speed, load direction, quantity and photos showing surrounding components. For bare cast housings, the machine-side mounting dimensions are especially important.
Evidence Note
The supplied catalog is the technical source of record for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB; its image crop is kept with the product so the dimensional evidence remains traceable. The gallery drawing for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB is a direct catalog crop, not an AI-generated technical illustration. Any application visualization added later for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB should be treated as illustrative rather than as dimensional evidence.
Evidence chain for S.UCP / S.UCF / S.UCFL / S.UCPW / S.UCT / S.UCFC / S.UCHA / S.UCFB: the user catalog on PDF pages 43-44 supports product geometry and dimensions, while the project Word file provides page organization. Drive and web sources are supplementary context only.